±ê×¼ÅäÖÃÐÔÄÜ£º
- ½ÚÄÜÐÔÄÜ
¡¡¡¡±ê×¼ÅäÖðüÀ¨¸ßÃܶȲ£Á§ÏËά±£Î²㣬ºñ¶È´ó£¬·ûºÏASHRAE£¨ÃÀ¹ú²Éů¡¢ÖÆÀäÓë¿Õµ÷¹¤³Ìʦѧ»á£©90.1b
1992±ê×¼£¬Äܹ»×î´ó³Ì¶È¼õÉÙÈÈÁ¿Ëðʧ¡£Õâ¸ö±ê×¼ÒªÇóÿƽ·½Ó¢³ßÄÚµ¨±íÃæÆ÷ÈÈÁ¿Ëðʧ×î´ó²»Äܳ¬¹ý4Íß¡£Òò´Ë£¬±¾×°Öøü¼Ó½ÚÄÜ£¬ÔËÐиü¼Ó¸ßЧ¡£
- ÅäÖýþÅÝʽÎÂ¿ØÆ÷µÄ´Å¿Ø¼ÌµçÆ÷
¡¡¡¡ÄÚÖñäѹÆ÷µÄ120·ü¿ØÖƵç·¡£¼ÓÈȰô¿Éͨ¹ýÎÂ¿ØÆ÷½øÐпØÖÆ£¬Æä¸ÐÓ¦±ä»¯ÔöÁ¿×î´óΪ54ǧÍß¡£
- µÍ¹¦ÂʸßÃܶÈÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰô
¡¡¡¡ÃÀ¹ú°ÙÀ´¸£¹«Ë¾Ö®ËùÒÔ²ÉÓÃÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰô£¬ÊÇÓÉÓÚÓ봫ͳµÄͿǼÓÈȰôÏà±È£¬ÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰô¾ßÓÐÐí¶àÓÅÒìµÄÐÔÄÜ£¬¸üÄܹ»ÊÊӦˮÖʽϲîµÄÓÃ;¡£ÕâÖÖÌØ±ðÄÍÓõĺϽðÄܹ»³É¹¦µØµÖ¿¹³¤Ê±¼ä¸ßΡ¢Ó²Ë®¡¢Ëá¡¢¸¯Ê´ÎïºÍÈȳå»÷Ëù²úÉúµÄÆÆ»µ×÷Ó᣾¡¹ÜÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰô¹ºÖóɱ¾±È½Ï¸ß£¬µ«ÊÇÓÉÓÚÕâÖÖ¼ÓÈȰôµÄÆÚÍûʹÓÃÊÙÃü¸ü³¤£¬Äܹ»¼õÉÙÈÕ³£Î¬»¤·ÑÓúÍÈ˹¤³É±¾£¬Òò´Ë×ܳɱ¾Êµ¼ÊÉϸü¼Ó¾¼ÃºÏËã¡£´ËÍ⣬ÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰôÄܹ»ÄÍÊÜÒ»¶¨³Ì¶ÈµÄ¡°¸ÉÉÕ¡±£¬Äܹ»ÓÐЧ·ÀÖ¹ÓÉÓÚȱˮ»òÎÞˮ״̬Ï¡°¸ÉÉÕ¡±¶ÔÉ豸Ôì³ÉµÄÆÆ»µ¡£
- ÄÚÖñ£ÏÕË¿
¡¡¡¡ËùÓмÓÈȰôºÍµç·¾ùÅäÖÃ48°²ÅàÔöÁ¿µÄ±£ÏÕË¿£¬Ìá¹©È«ÃæµÄµçÆø±£»¤¡£ºÐ×´±£ÏÕ˿װÖö¶Ï¿ªÈÝÁ¿Îª20Íò°²Åà¡£
- ²£Á§³ÄÀïÄÚµ¨
¡¡¡¡±¾É豸µÄ¸ÖÖÆÄÚµ¨±íÃæÄÚ³ÄÒ»²ã²£Á§£¬ÔÚ1600oF (871oC)
¸ßÎÂÉÕÖÆ³ÉÒ»Ìå¡£ËùÓÐÐͺŶ¼°´ÕÕASME£¨ÃÀ¹ú»úе¹¤³Ìʦлᣩ±ê×¼Éú²úÖÆÔ죬²¢Í¨¹ý125
PSI¹¤×÷ѹÁ¦²âÊÔ¡£
- ÄÚÖð²È«ÉèÊ©ÅÅË®ÅÌ£¨½öÊÊÓÃÓÚ·½ÐÎÈÈË®Æ÷£©
¡¡¡¡ËùÓÐÐͺŵij¬ÖØÐÍÈÈË®Æ÷¾ùÄÚÖÃÃÜ·âÅÅË®ÅÌϵͳ£¬²¢ÅäÖÃ3/4Ó¢´ç¿Ú¾¶µÄÅÅË®Á¬½Ó¿Ú¡£ÕâÓÐÖúÓÚ·ÀÖ¹ÓÉÓÚÄÚµ¨»òÆäËû²¿¼þй©ËùÔì³ÉµÄÆÆ»µ¡£Ô²ÐÎÈÈË®Æ÷ûÓÐÅäÖÃÕâÖÖÉèÊ©¡£
- þÖÊÄÚµ¨½ÚÄÜ×°ÖÃ
¡¡¡¡ÕâÖÖ×°ÖÃÄܹ»ÌṩÑô¼«±£»¤£¬·ÀÖ¹µç½â×÷ÓöÔÄÚµ¨Ôì³ÉµÄ¸¯Ê´ÆÆ»µ¡£
- µç¶ÆÍâ¿Ç
¡¡¡¡Íâ¿ÇÓÉ16¶È¸Ö°åÖÆ×÷¶ø³É£¬²¢ÔÚÍâ¿ÇÄÚÍâ¾ù½øÐо«ÖÂµÄµç¶Æ£¬Òò´ËÍâ¿Ç¸²¸Ç±ûÏ©Ëá´ÅÆá£¬Ê¹±íÃæ¹â½àƯÁÁ¡£ÕâÑùµÄÍâ¿Ç²»½öÃÀ¹Û£¬¶øÇÒ×î´óÏÞ¶ÈΪÈÈË®Æ÷ÌṩÓÐЧµÄ±£»¤¡£
- ¸ß¶È×ã¹»µÄ½ÂÁ´ÃÅ£¬ÅäÖÃËø¼°Ô¿³×
¡¡¡¡·ûºÏ¸ßÖÊÁ¿±ê×¼¡¢¾ßÓÐ×ã¹»¸ß¶ÈµÄ½ÂÁ´ÃÅ£¬ÓÐÀûÓÚ¹Û²ì¼à²âºÍά»¤¡£ÅäÖõÄËø¾ß¼°Ô¿³×ʹ°²È«ÐԵõ½½øÒ»²½µÄ±£ÕÏ£¬²»ÐèÒªÔÚÔö¼Ó¶îÍâµÄ·ÑÓá£
- ¹ýÈȺͳ¬Ñ¹°²È«·§
¡¡¡¡ÃÀ¹ú°ÙÀ´¸£¹«Ë¾ÔÚ±¾¿îÈÈË®Æ÷ÉÏÅäÖÃͨ¹ýASME£¨ÃÀ¹ú»úе¹¤³ÌʦлᣩÈÏÖ¤µÄ°²È«·§£¬µ±ÄÚµ¨ÈÝÆ÷ÄÚ³öÏÖζȹý¸ß»òÀÛ»ýѹÁ¦¹ý´óµÆÒì³£Çé¿öʱ£¬½øÐнµÎºͼõѹ£¬Ìṩ¿É¿¿µÄ°²È«±£»¤¡£
- ¶Ë×Ó½ÓÏߺÐ
¡¡¡¡ÕâÖÖÔÚ¹¤³§¾ÍÅäÖúõĶË×Ó½ÓÏߺУ¬Ê¹µÃµçÔ´Á¬½Ó¸ü¼Ó·½±ã£¬¸ü¼Ó°²È«¡£
- ÔËÐÐË®ÎÂΪ180oF (100oC)
¡¡¡¡Ã¿Ì¨³¬ÖØÐÍÈÈË®Æ÷¶¼¿ÉΪÎÀÉú´¦ÀíºÍÆäËû¸ßÎÂÈÈË®ÐèÇóÌṩ180oF (100oC)¸ßÎÂÈÈË®¡£
- È˹¤ÇåÏ´¿×
¡¡¡¡Ê¹È˹¤¹Û²ìºÍÇåÏ´ÈÈË®Æ÷ÄÚ²¿¸ü¼Ó·½±ã¡£
- ²Û¸Öµ¼¹ì»ù×ù
¡¡¡¡Ö»ÊÊÓÃÓÚ250¼ÓÂØÒÔÉϵĵçÈÈË®Æ÷¡£
- ͨ¹ýÃÀ¹úUL°²È«ÈÏÖ¤
¡¡¡¡ËùÓÐÐͺÅ×÷ΪÉÌÓõçÈÈË®Æ÷¾ù»ñµÃÃÀ¹úUL£¨ÃÀ¹ú±£ÏÕÉÌʵÑéÊÒ£©µÄ°²È«ÈÏÖ¤¡¡Õâ±íÃ÷ÕâЩ²úÆ·ÔڽṹÉè¼ÆºÍ²úÆ·ÖÊÁ¿¼ìÑé·½Ãæ¾ùÓпɿ¿µÄ±£ÕÏ¡£
- ÈýÄêÓÐÏÞÖÊÁ¿±£Ö¤
¡¡¡¡¶ÔÓÉÓÚ²ÄÁÏȱÏݺ͹¤ÒÕȱÏÝËùÔì³ÉµÄÈÝÆ÷¹ÊÕÏÌṩÖÊÁ¿±£Ö¤¡£
±¸Ñ¡É豸¹¦ÄÜ£º
- µÍË®Á¿µçÔ´×Ô¶¯ÇжϹ¦ÄÜ
¡¡¡¡Äܹ»·ÀÖ¹ÈÝÆ÷ÄÚûÓÐË®»òˮλºÜµÍËùÔì³ÉµÄ¡°¸ÉÉÕ¡±ÏÖÏó¡£
- µ¼ÏòµÆ
¡¡¡¡ÓÃÓÚ¼àÊÓÿ¸öµçÁ÷½Ó´¥Æ÷µÄµçÔ´¿ª¹Ø×´Ì¬¡£
- È˹¤ÏÞÖÆ¿ª¹Ø
¡¡¡¡ÅäÖÃָʾµÆ£Ê¹µÃÄܹ»Í¨¹ý¿ª¹ØÃ¿¸öµçÁ÷½Ó´¥Æ÷µÄµçÔ´´ïµ½È˹¤¿ØÖÆÊäÈ빦ÂʵÄÄ¿µÄ¡£
- ¹ÌÌå״̬µ÷½Ú¿ØÖÆ×°Ö㨵ç×Ó³ÌÐò×°Öã©
¡¡¡¡µ÷½ÚµçÁ¦ÊäÈ룬ƽºâËùÐ踺ºÉ¡£µçÁ÷½Ó´¥Æ÷Öð¼¶Ë³Ðò×Ô¶¯Æ½ºâ¼ÓÈȰôµÄʹÓÃÂÊ¡£²¢ÇÒÔÚ³öÏÖµçÁ¦¹©Ó¦¹ÊÕÏʱ£¬±¾×°ÖÃÄܹ»ÖØÐ±à³Ì»Ö¸´³õʼ״̬¡££¨½öÊÊÓÃÓÚ36ǧÍßÒÔÉϵÄÈÈË®Æ÷¡££©
- ¾¯±¨Áå
¡¡¡¡µ±³öÏÖ¸÷ÖÖ¿ØÖƹÊÕÏʱ£¬ÌṩÉùÒô¾¯±¨¡£
- ²¢ÁªÌøÕ¢×°ÖÃ
¡¡¡¡Ò»µ©¿ØÖÆ×°Öüà²âµ¼ÓιÊÕÏ·¢Éú»òµçÁ÷¹ýÔØ£¬½«×Ô¶¯ÇжÏËùÓÐÁ¬½ÓÈÈË®Æ÷µÄËùÓеçÔ´£¬×î´óÏ޶ȱ£»¤ÈÈË®Æ÷¡££¨ÐèÒª¶ÀÁ¢°²×°¡££©
- µÍѹ»ò¸ßѹ¿ª¹Ø
¡¡¡¡ÓÃÓÚµ±Ë®Ñ¹½µµÍµ½Ô¤ÏÈÉèÖõÄ×îµÍÖµ»ò³¬¹ýÔ¤ÏÈÉèÖõÄ×î¸ßֵʱ£¬ÇжϿØÖƵçÁ÷¡£
- ¼ÆÊ±Æ÷
¡¡¡¡¸ù¾ÝÓû§ºÍµçÁ¦¹©Ó¦ÒªÇóµÄÔ¤ÏÈÉèÖ㬿ØÖÆÈÈË®Æ÷µÄ¿ª¹ØÊ±¼ä¡££¨¶ÀÁ¢°²×°£©£¨7Ìì»ò24Сʱ£©
- Á¬Ëø°²È«ÃÅ
¡¡¡¡·ÀÖ¹ÔÚµçԴδÇжÏ״̬Ï£¬°²È«Ãű»´ò¿ª¡£
- ζȺÍѹÁ¦±í
¡¡¡¡¿É°²×°ÔÚÈÈË®Æ÷±íÃæ£¬±ãÓڹ۲졣
- È˹¤¿×£¨½öÏÞÓÚ·½ÐÎÈÈË®Æ÷£©
¡¡¡¡±ãÓÚÇå³ýÈÈË®Æ÷ÉϵijÁµíÎï¡£±¾×°ÖöÔÓÚ250¼ÓÂØÖÁ400¼ÓÂØÈÈË®Æ÷ʱ±¸Ñ¡ÅäÖ㬶ÔÓÚ500¼ÓÂØÒÔÉϵÄÈÈË®Æ÷ÊDZê×¼ÅäÖᣲ»ÊÊÓÃÓÚÔ²ÐÎÈÈË®Æ÷¡£
- ¸½¼ÓÈ˹¤Ô¤ÖøßÎÂÏÞÖÆ
¡¡¡¡ÓÃÓÚÈ˹¤ÉèÖÃÈÈË®Æ÷µÄ×î¸ßζÈÏÞÖÆ¡£
- ÌáÉýµõ»·
¡¡¡¡£¨²»ÊÊÓÃÓÚÔ²ÐÎÈÈË®Æ÷£©¡£¶ÔÓÚ600¼ÓÂØÒÔÉϵÄÈÈË®Æ÷ÊDZê×¼ÅäÖá£
- ¹¤×÷ѹÁ¦
¡¡¡¡·ûºÏASME£¨ÃÀ¹ú»úе¹¤³Ìʦлᣩ150 PSI»ò160
PSIѹÁ¦¹æ¶¨¡£
¶ÀÁ¢°²×°£ÏÖ³¡°²×°
|
|
Standard Equipment Features
Energy-saving performance ¨C a heavy blanket
of high-density fiberglass insulation is used to meet the demanding ASHRAE
90.1b 1992 standard for minimizing heat loss. This requirement, allowing
a maximum 4 watts per square foot of tank surface energy loss, offers
big savings and operating efficiency.
Magnetic contactors with immersion thermostats
¨C 120 volt control circuit with built in transformer. Elements are thermostatically
controlled in 54KW (max) increments.
Low watt density Incoloy elements ¨C Incoloy
elements are used by Bradford White because of their many superior characteristics
to copper-sheathed elements in rigorous water heating applications. This
tough alloy
successfully resists the effects of prolonged high operating temperatures,
hard water, acids, corrosion, and thermal shock. Their nominally higher
initial cost is more than offset by much longer life expectancies and
reduced service and replacement labor costs. Incoloy elements are designed
to ¡°burn in air¡± to prevent failures caused by water void.
Internal fusing ¨C all elements and circuits
are fused in
48 amp. increments, providing complete electrical protection. Cartridge
type fuses are rated at 200,000 ampere interrupting capacity.
Glass-lined tank ¨C vitreous glass is applied
to the inside surface of the steel tank and fired to 1600¡ãF. (All models
are constructed in accordance with the ASME code and approved for 125
PSI working pressure.)
Built-in safety drain pan (square only) ¨C
all Brute Heater models feature a built-in, sealed drain pan system...complete
with a 3/4" drain connection. This assists in protecting against
water damage from tank or component leakage. Not available on round models.
Magnesium tank saver ¨C provides anodic protection
against corrosion of the tank due to electrolysis.
Galvanized jacket ¨C the heavy 16-gauge steel
jacket is galvanized on both sides and beautifully finished in durable
acrylic enamel. This combines attractive appearance with maximum protection.
Full-length hinged door with key lock ¨Cquality
requires full-length hinged doors for ease of inspection and maintenance.
Key Door Lock provides additional safety and security at no extra charge.
Temperature and pressure relief valve ¨Cfactory
provided ASME rated relief valve protects against excessive temperature
and/or pressure buildup within the tank.
Terminal block connections ¨C easy and safe
wiring connections are made possible by factory installed terminal blocks.
180¡ãF temperature operation ¨C every Brute
Heater is approved for 180¡ãF. operation for sanitizing and other high-temperature
requirements.
Hand hole cleanout ¨C provides easy access
to the heater interior for inspection and cleaning.
Channel iron skid base - available for 250
gallons and larger.
UL listed - all models are listed by Underwriters
Laboratories, Inc. as commercial electric water heaters...your assurance
of competent design and proper testing.
Three-year limited warranty - provides warranty
protection against tank failure resulting from defects in
material and workmanship.
Optional Equipment Features:
Low water cut off - prevents energizing of
the heater when not filled with water or upon low water condition.
Pilot lights - monitor on/off cycle for each
contactor.
Manual limiting switches - with indicating lights
–
permits manually limiting heating input by switching off
current to each contactor.
Solid state modulating control (electronic sequencer)
- modulates power input and balances load to demand. Contactors are staged
automatically and sequentially to equalize element usage. Unit reprograms
to off position on power failure. (Available only for 36 KW or
higher)
Alarm bell - warns of various control failures.
Shunt trip disconnect - provides maximum
protection by interrupting all power to the system in the event of a control
sensed malfunction or overcurrent. (Separate mounting).
Low or high pressure switch - turns off control
circuit when water pressure drops below a set minimum, or
above a set maximum.
Time clock - to control off/on cycles of
the heater as programmed by the owner or electric utility requirements.
(Separate mounting) (7 day or 24 hour)
Safety door interlock - prevents opening
of access door while heater is energized.
Temperature and pressure gauges - jacket
mounted for convenient viewing.
Man hole (square only) - provides means to
easily remove sediment from the heater; optional on 250 to 400 gallon
models; standard on 500 gallons and larger. Not available on round models.
Additional manual reset hi limit - requires
heater to be manually reset upon over-temperature condition.
Lifting Lugs - (not available on vertical
round models). Standard on 600 gallons and larger.
Working pressure - 150 PSI or 160 PSI ASME
construction.
Separate mounting - Field Installed.
|