ÃÀ¹ú°ÙÀ´¸£Bradford WhiteÉÌÓýÚÄܵçÈÈË®Æ÷
ÎÂ¿ØÆ÷ºÍ´ø½»Á÷½Ó´¥Æ÷µÄ½þÅÝʽÎÂ¿ØÆ÷°²×°ÔÚÈÈË®Æ÷±íÃæ
Commercial Energy Saver Electric
Surface Mounted Thermostats and Immersion Thermostats with Contactors

¡¡¡¡´ïµ½»ò³¬¹ýASHRAE±ê×¼ÈÏÖ¤£¨ÃÀ¹ú²Éů¡¢ÖÆÀäÓë¿Õµ÷¹¤³Ìʦѧ»á£©±ê×¼90.1b 1992¹æ¶¨µÄÐÔÄܱê×¼

ÐÔÄÜ£º

¡¡¡¡ÃÀ¹ú°ÙÀ´¸£¹«Ë¾Í¨¹ýISO9001ÈÏÖ¤¡£

  • ±íÃæ°²×°µÄÎÂ¿ØÆ÷ÓÃÓÚ¶ÔˮνøÐÐÖð¼¶µ÷¿Ø
    ¡¡¡¡ÔÚÎÂ¿ØÆ÷ÉÏ¿ÉÒÔ½øÐи÷ÖÖµ÷¿Ø¡££¨Ã¿¸ö¼ÓÈȰô¶¼Óи÷×Ô¶ÀÁ¢µÄÎÂ¿ØÆ÷£¬¿ÉÒÔ¸÷×Ô¶ÀÁ¢ÉèÖÃ×î¸ßζȡ££©
  • ½þÅÝʽÎÂ¿ØÆ÷
    ¡¡¡¡½þÅÝʽÎÂ¿ØÆ÷ʹµÃÓû§Äܹ»È˹¤ÉèÖÃ×î¸ßζȣ¬Î¶ÈÉèÖ÷¶Î§ÔÚ0¡«82oC¡£
  • 3Ó¢´ç£¨76mm£©ºñµÄÎÞ·úÅÝÄ­±£Î²ÄÁÏ
  • Vitraglas®£¨Î°×¿£©ÄÚµ¨
    ¡¡¡¡ÃÀ¹ú°ÙÀ´¸£ÈÈË®Æ÷ÄÚµ¨Í¿·óÓÐÒ»²ã¶ÀÌØµÄÌÕ´ÉÒ»ÑùµÄ±íÃæ£¬Äܹ»ÓÐЧ·ÀÖ¹ÈÈË®µÄ¸¯Ê´×÷Óá£ÃÀ¹ú¡°°ÙÀ´¸£¡±¸ß¼¶¶þÑõ»¯¹èVitraglas®£¨Î°×¿£©ÄÚµ¨Ê¹µÃÈÈË®Æ÷µÄÄÚµ¨±íÃæÌØ±ð¼á¹ÌÄÍÓã¬Äܹ»¾­ÊÜÈÝÆ÷ÄÚÈÈË®µÄ¸ßκ͸ßѹµÄ¸¯Ê´×÷Óá£
  • ÔÚ¹¤³§°²×°µÄHydrojet®£¨ÅçË®ÉäÁ÷£©·À³Áµíϵͳ
    ¡¡¡¡ÕâÖÖϵͳÓÐÀûÓÚ¼õÉÙÀäË®´øÈëµÄ³ÁµíÎÓÐÖúÓÚ×î´óÏ޶ȼõÉÙÈÈË®Æ÷ÄÚµ¨²úÉúË®¹¸£¬ÓÐÀûÓÚÔö¼ÓÈÈË®¹©Ó¦Á¿£¬¼õÉÙÁ÷½øµÄÀäË®¶Ôˮα仯µÄ²»ÀûÓ°Ïì¡£
  • ÔÚ¹¤³§°²×°µÄ¾øÔµ×°ÖÃ
    ¡¡¡¡ËùÓÐÈÈË®Æ÷¶¼ÅäÖÃÌØÖÆµÄÈÈË®Æ÷½ÓÍ·£¬ÓÐÀûÓÚÑÓ³¤ÈÈË®Æ÷µÄʹÓÃÊÙÃü¡£²»ÐèÒªÁíÍ⹺ÂòÌØÖÆµÄ¾øÔµ×°Öá£
  • ¼ÓÈȰô
    ¡¡¡¡ÂÝ¿ÚÐÍ¡£ÎÂ¿ØÆ÷°²×°ÔÚÈÈË®Æ÷±íÃæµÄÈÈË®Æ÷µÄ¼ÓÈȰôÓÉÄø¸õºÏ½ð²ÄÁÏÖÆ³É£¬ÄÚÖÃÑõ»¯Ã¾£¬Í⸲µç¶ÆÍ­£¬×î´óÏÞ¶ÈÑÓ»ºÑô¼«°ôµÄË¥¼õÏÖÏó¡£±¸ÓÐÍ⸲ÄÍÈÈÄø¸õÌúºÏ½ð²ÄÁϵļÓÈȰô¹©Óû§Ñ¡Ôñ¡£½þÅÝʽÎÂ¿ØÆ÷ÀàÐ͵ÄÈÈË®Æ÷ÅäÖõ͹¦ÂÊÃÜʵÄÍÈÈÄø¸õÌúºÏ½ð¼ÓÈȰô£¬ÓÐÀûÓÚµÖ¿¹¸ÉÉÕ»òʯ»Ò³Á»ý¶ÔÈÈË®Æ÷µÄË𻵡£
  • Á½¸ù½ðÊôþÑô¼«°ô
    ¡¡¡¡ÕâÖÖ½ðÊôþÑô¼«°ôÄܹ»Ìá¸ßÈÈË®Æ÷µÄÄ͸¯Ê´ÄÜÁ¦£¬ÑÓ³¤ÈÈË®Æ÷µÄÎÞ¹ÊÕÏÊÙÃü¡£
  • È˹¤ÇåÏ´¿×
  • ÓÐÈýÖÖÈÝ»ý50¡¢80ºÍ119¼ÓÂØ£¨189¡¢303ºÍ450¹«Éý£©µÄÈÈË®Æ÷¹©Óû§Ñ¡Ôñ
  • ±¸ÓÐÂú×ãNSF£¨ÃÀ¹ú¹ú¼Ò¿ÆÑ§»ù½ð»á£©±ê×¼µÄ½¨ÖþÎïËùʹÓõÄÈÈË®Æ÷¹©Ñ¡Ôñ
  • »ÆÍ­ÅÅË®·§
  • ¹¤³§°²×°µÄ½µÎ¼õѹ°²È«·§
  • ÍêÕûµÄÔ¤ÖõçÔ´Ïß
    ¡¡¡¡½ÓÏߺÐÄÚÅäÖÃÄÍѹ½ÓÏ߯¬£¬²»ÐèÒªÁ¬½ÓºÍ²øÈƵçÔ´Ïß¡£
  • ÃÀ¹úUL°²È«ÈÏÖ¤
    ¡¡¡¡ËùÓÐÃÀ¹ú°ÙÀ´¸£ÉÌÓõçÈÈË®Æ÷¾ùͨ¹ýÃÀ¹úUL°²È«ÈÏÖ¤£¬¾ßÓÐÃÀ¹úULÈÏÖ¤±êÖ¾¡£¼È¿Éµ¥¶À°²×°Ê¹Óã¬Ò²¿É¶àÖØ°²×°Ê¹Ó㻿ÉÒÔʹÓÃÒ²¿ÉÒÔ²»Ê¹ÓöÀÁ¢µÄÄÚµ¨¡£
  • ÄÚµ¨3ÄêÓÐÏÞÖÊÁ¿±£Ö¤
    ¡¡¡¡ÓÅÖʲ£Á§ÖÊÄÚµ¨ÈÈË®Æ÷ʹµÃ±¾¿îÈÈË®Æ÷ÎïÓÐËùÖµ¡£Èç¹ûÓÉÓÚ²ÉÓÃÁÓÖʲÄÁÏ¡¢ÖÆ×÷ʧÎó»òÔÚ±£ÖÊÆÚÄÚ±»¸¯Ê´¶øÔì³ÉµÄÄÚµ¨Ð¹Â©£¬½«Ãâ·Ñ¸ü»»ÃÀ¹ú°ÙÀ´¸£¹«Ë¾ÖÆÔìµÄͬÐͺŻò¸üºÃµÄÈÈË®Æ÷£¨²»°üÀ¨ËùÓÐÔËÊä·ÑÓúÍÖØÐ°²×°µÄ·ÑÓã©¡£Çë²ÎÔÄÿ̨ÈÈË®Æ÷ÄÚËæ»úÌṩµÄÓÐÏÞÖÊÁ¿±£Ö¤µÄÍêÕûÌõ¿î¡£
  • Åä¼þ1ÄêÓÐÏÞÖÊÁ¿±£Ö¤
    ¡¡¡¡ÕâЩÅä¼þ¶¼ÓÉÃÀ¹ú¸ÃÅä¼þÐÐÒµµÄ×îºÃÆóҵΪÃÀ¹ú°ÙÀ´¸£¹«Ë¾×¨ÃÅÖÆÔì¡£Èç¹ûÕâЩÅä¼þÔÚ±£ÖÊÆÚÄÚ³öÏÖ¹ÊÕÏ£¬½«Ãâ·Ñ½øÐиü»»£¨²»°üÀ¨ËùÓÐÔËÊä·ÑÓúÍÖØÐ°²×°µÄ·ÑÓã©¡£

±¾¿îÈÈË®Æ÷²ÉÓÃÏÂÁÐÃÀ¹úרÀû¼¼ÊõÖÆÔ죺
Re. 34,534; 4,416,222; 4,628,184; 4,669,448; 4,672,919; 4,808,356; 4,829,983; 4,861,968; 4,904,428; 5,000,893; 5,023,031; 5,052,346; 5,081,696; 5,092,519; 5,115,767; 5,199,385; 5,277,171; (B1)5,341,770; 5,372,185; 5,485,879; 5,574,822; 5,596,952; 5,660,165; 5,682,666; 5,761,379; 5,943,984; 5,954,492; 5,988,117; 6,142,216.


£¨ä¯ÀÀ´óͼƬLarge£©

¡¡¡¡

½ÚÄÜÉÌÓõçÈÈË®Æ÷
ÐͺÅ
Model
ÈÝ»ý
Capacity
A
ÈÈË®Æ÷
Íâ¾¶
Jacket Dia
B
ÈÈË®Æ÷
¸ß¶È
Height Top
C
¿ØÖƺÐ
¸ß¶È
Fl. to Top
of Control Box
D
ÈÈË®³ö¿Ú
¸ß¶È
Fl. to HW
Outlet
E
°²È«·§
¸ß¶È
Ht. Fl. to
T&P Valve
Ë®½Ó¿Ú
¿Ú¾¶
Water
Conn.
±ê×¼´óÖÂ
×°´¬ÖØÁ¿
Approx.
Shipping
Weight
Std.
ASME´óÖÂ
×°´¬ÖØÁ¿
Approx.
Shipping
Weight
ASME
¼ÓÂØ.
Gal.
¹«Éý
Liters
Ó¢´ç
in.
ºÁÃ×
mm.
Ó¢´ç
in.
ºÁÃ×
mm.
Ó¢´ç
in.
ºÁÃ×
mm.
Ó¢´ç
in.
ºÁÃ×
mm.
Ó¢´ç
in.
ºÁÃ×
mm.
Ó¢´ç
in.
ºÁÃ×
mm.
°õ
lbs.
¹«½ï
Kg.
°õ
lbs.
¹«½ï
Kg.
M-II-50(A)-KW 50 189 24 610 47 3/4 1213 46 1/2 1181 49 1/4 1251 41 1041 1 1/2 38 270 122 302 137
M-II-80(A)-KW 80 303 26 660 60 1/4 1530 46 1/2 1181 61 3/4 1568 52 1/2 1334 1 1/2 38 335 152 378 171
M-II-120(A)-KW 119 450 30 1/4 768 64 1/2 1638 50 1/4 1276 66 1676 55 1397 1 1/2 38 430 105 485 220

¡¡¡¡°²È«·§µÄµÄ¹«³ÆÍ¨¾¶Îª3/4Ó¢´ç£¬¹¤×÷ѹÁ¦Îª150 PSI£¬ÊÔÑéѹÁ¦Îª300 PSI¡£½µÎ¼õѹ°²È«·§·ûºÏÃÀ¹úULÈÏÖ¤µÄÒªÇó¡£
¡¡¡¡ËùÓгߴçµÄµ¥Î»ÎªÓ¢´çºÍºÁÃס£
¡¡¡¡(A) ±íʾ¿ÉÂú×ãASME±ê×¼µÄÈÈË®Æ÷Ðͺš£
¡¡¡¡1ÃÀÖÆ¼ÓÂØ = 3.785¹«Éý

Relief Valve Opening 3.4". 150 PSI Working Pressure. 300 PSI Test Pressure. Temperature and pressure relief valve supplied in accordance with U.L. requirements. All dimensions in inches/mm.
(A) ASME Available
µçÔ´ÌØÐÔ
¼ÓÈȰôÊýÁ¿£¨±£ÏÕË¿ÀàÐÍ£©*
Number of Elements (Fused Models)*

ÊäÈ빦ÂÊ
£¨KW£©
Input
(KW)

208V ÏàÊý
208 Volts Phase
240V ÏàÊý
240 Volts Phase
277V ÏàÊý
277 Volts Phase
380V ÏàÊý
380 Volts Phase
415V ÏàÊý
415 Volts Phase
480V ÏàÊý
480 Volts Phase
1 3 1 3 1 1 3 1 3 1 3
6 3(2) 3 3(2) 3 3 3 3 3 3 3(2) 3
9 3 3 3 3 3 3 3 3 3 3 3
12 3 3 3(2) 3 3 3 3 3 3 3(2) 3
13.5 3 3 3 3 3 3 3 3 3 3 3
15 3 3 3 3 3 3 3 3 3 3 3
18 3 3 3 3 3 3 3 3 3 3 3
24 4 6 4 6 4 4 6 4 6 4 6
27 6 6 6 6 6 6 6 6 6 6 6
30 6 6 6 6 6 6 6 6 6 6 6
36 6 6 6 6 6 6 6 6 6 6 6
45 9 9 9 9 9 9 9 9 9 9 9
54 9 9 9 9 9 9 9 9 9 9 9
È«¸ººÉ״̬ϵĵçÁ÷°²Åࣨ±£ÏÕË¿ÀàÐÍ£©*
Full Load Current Amperes (Fused Models)*

ÊäÈ빦ÂÊ
£¨KW£©
Input
(KW)

208V ÏàÊý
208 Volts Phase
240V ÏàÊý
240 Volts Phase
277V ÏàÊý
277 Volts Phase
380V ÏàÊý
380 Volts Phase
415V ÏàÊý
415 Volts Phase
480V ÏàÊý
480 Volts Phase
1 3 1 3 1 1 3 1 3 1 3
6 28.8 16.6 25.0 14.4 21.6 16.0 10.0 15 9 12.5 7.2
9 43.2 25.0 37.2 21.6 32.4 24.0 14 22 13 18.7 10.8
12 57.6 33.3 50.0 28.9 43.3 32.0 19 29 17 25.0 14.4
13.5 64.9 37.5 56.2 32.5 48.7 36.0 21 33 19 28.1 16.2
15 72.1 41.6 62.5 36.1 54.1 40.0 23 36 21 31.2 18.0
18 86.5 50.0 75.0 43.4 64.0 48.0 28 44 25 37.5 21.6
24 115.4 66.7 100.0 57.8 86.6 63.0 37 58 34 50.0 28.9
27 129.8 75.0 112.5 65.0 97.4 71.0 41 65 38 56.2 32.5
30 144.2 83.3 125.0 72.2 108.3 79.0 46 72 42 62.5 36.1
36 173.0 100.0 150.0 86.7 129.9 95.0 55 87 50 75.0 43.3
45 216.3 125.0 187.5 108.3 162.4 119.0 69 109 63 93.7 54.1
54 259.6 150.0 225.0 130.0 194.9 142.0 83 130 75 112.5 65.0

¡¡¡¡µçÁ÷°²ÅàÊý³¬¹ý48°²ÅàµÄÈÈË®Æ÷ÐèÒªÔÚ¹¤³§°²×°ÄÚÖñ£ÏÕË¿¡£
¡¡¡¡*Èç¹ûÎÞ±£ÏÕË¿ÐͺŵÄÈÈË®Æ÷µÄ¼ÓÈȰôÊýÁ¿ÓÐËù²»Í¬£¬ÔòÔÚÔ²À¨ºÅ£¨£©ÄÚ¼ÓÒÔ±íʾ¡£

Units with amperage draw of 48 amps or more require factory installed internal fusing.
*If the number of elements on non-fused models is different, it is indicated in parentheses ( ), following the AMP draw.
ÿСʱËù²úÉúµÄÈÈË®Á¿£¨ÃÀÖÆ¼ÓÂØ£©
ÊäÈ빦ÂÊ
KW
Input
Ë®ÎÂÉý¸ßµÄ¶ÈÊý
TEMPERATURE RISE
40oF 50oF 60oF 70oF 80oF 90oF 100oF 120oF 140oF
6 62 50 41 35 31 28 25 21 18
9 93 74 62 53 47 41.7 37 31 27
12 124 99 83 71 62 55 50 41 35
13.5 140 112 93 80 70 62 56 47 40
15 155 124 103 89 78 69 62 52 44
18 186 149 124 106 93 83 74 62 53
24 248 199 164 142 124 110 99 83 71
27 279 223 186 160.4 140 124 112 93 80
30 310 248 207 177 155 138 124 103 89
36 372 298 248 213 186 165 149 124 106
45 465 372 310 266 233 207 186 155 133
54 558 447 372 319 279 248 223 186 160

¡¡¡¡£¨±¸ÓÐζȵ÷½Ú·¶Î§´Ó80oFÖÁ140oFµÄÎÂ¿ØÆ÷¹©Óû§Ñ¡Ôñ¡££©

(Optional thermostats ranging from 80¡ã to 140¡ãF. are available)

¡¡¡¡¶©¹ºËµÃ÷Êé·¶±¾
¡¡¡¡ËùÒª¶©¹ºµÄÈÈË®Æ÷ÊÇÃÀ¹ú°ÙÀ´¸£ÈÈË®Æ÷£¬ÈÝ»ý²»Ð¡ÓÚ________________¼ÓÂØ£¯¹«Éý£¬×îСÊäÈ빦ÂÊÊÇ____________KW£¬×îСÈÈЧÂÊÊÇÿСʱ²úÉú____________¼ÓÂØ£¯¹«Éý¡¢Î¶ÈÉÏÉý·ù¶ÈΪ100oF (56oC)µÄÈÈË®¡£ËüÄܹ»ÓëÆäËüÈÈË®Æ÷²¢Óã¬Ò²¿ÉÒÔµ¥¶ÀʹÓá£ÈÈË®Æ÷ÄÚµ«±ØÐëÊÇVitraglas®£¨Î°×¿£©Ì´ÉÄÚµ¨²¢ÅäÖÃÂÝÎÆÈ˹¤ÇåÏ´¿×¡£ÄÚµ¨Ó¦¸ÃÅäÖÃÍ»³öÐÍþÑô¼«°ô£¬°²×°ÔÚ¶ÀÁ¢µÄÁ¬½Ó¿ÚÉÏ£¬²¢ÑÓÉìÖÁÀëÄÚµ¨µ×²¿ÈýÓ¢´ç£¨76mm£©µÄµØ·½¡£ÈÈË®Æ÷¾øÔµ²ãÓ¦¸Ã²ÉÓÃÎÞ·úÅÝÄ­±£Î²ÄÁÏ£¬ºñ¶È×îС²»µÃСÓÚ3Ó¢´ç£¨76mm£©¡£Õâ¸öÈÈË®Æ÷Ó¦¸ÃÅäÖÃͨ¹ýASME£¨ÃÀ¹ú»úе¹¤³ÌʦЭ»á£©ÈÏÖ¤µÄ¹ýÈÈ£¯³¬Ñ¹°²È«·¨£¨T&P·§£©¡£ËùÓа²×°²Ù×÷±ØÐë°´ÕÕÖÝ»òµ±µØ·¨¹æÌõÀýµÄÒªÇó½øÐС£ÎªÁ˸ÄÉÆ²úÆ·ÐÔÄÜ£¬ÎÒÃDz»¶Ï¶Ô²úÆ·½øÐиĽø£¬Òò´Ë²úÆ·¼¼Êõ¹æ¸ñ²ÎÊýÈôÓб䶯»ò¸ü¸Ä£¬Ë¡²»ÁíÐÐ֪ͨ¡£

These water heaters meet or exceed the performance standards established under ASHRAE Standard 90.1b 1992.

Features:

Bradford White is ISO registered to the 9001-1994 standard.

 Surface mounted thermostat step control (modulation) - can be accomplished by variable setting on thermostats (each element has an individual thermostat and high limit.)
 Immersion thermostats - Immersion type for accurate temperature control from positive off to 180oF (82oC) with manual reset high limit control.
 3" (76mm) Non-CFC foam insulation.
 Vitraglas® lined tank - Bradford White water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. The Bradford White high silica Vitraglas® lining provides a tough interior surface for water heater tanks, which must withstand the wearing effects of high volume and high temperature hot water.
 Factory installed Hydrojet® Sediment Reduction System - cold inlet sediment reduction device. Helps minimize sediment build up in tank.
 Factory installed dielectric fittings - all heaters equipped with special water heater nipples for longer heater life. No special dielectric fittings to buy.
 Elements - screw in style. Surface mounted thermostat models have elements made of nickel chromium wire embedded in magnesium oxide, sheathed in copper and electroplated to minimize degradation of the anode. Incoloy sheathed elements are optional. Immersion thermostat models have low watt density incoloy sheathed elements standard which resists burnout caused by dry fire or lime buildup.
 Two magnesium anode rods - employed to provide an extra measure of corrosion prevention for longer life.
 Hand hole cleanout opening.
 50, 80 and 119 gallon capacities (189, 303 and 450 Liters)
 ASME construction available - on surface and immersion thermostat models.
 NSF construction available.
 Brass drain valve.
 Factory installed temperature and pressure relief valve.
 Completely pre-wired - with pressure lug terminal block eliminating need for splicing or taping of wires.
 UL Listed - All Bradford White commercial electric water heaters are listed by Underwriters Laboratories and bear the UL label. They may be installed singly or in multiples, with or without a separate storage tank.
 Three year limited warranty - protects your investment in a quality glass lined heater. If the tank leaks for reasons of faulty materials, workmanship or corrosion within the warranty period, the heater will be replaced with a comparable heater of our manufacture. (Exclusive of all shipping and reinstallation costs). See complete copy of the warranty included with the heater.
 One year limited parts warranty - These quality components are manufactured for us by industry leaders and will be replaced in the event of failure during the parts warranty period (exclusive of shipping and re-installation cost.)

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS:
Re. 34,534; 4,416,222; 4,628,184; 4,669,448; 4,672,919; 4,808,356; 4,829,983; 4,861,968; 4,904,428; 5,000,893; 5,023,031; 5,052,346; 5,081,696; 5,092,519; 5,115,767; 5,199,385; 5,277,171; (B1)5,341,770; 5,372,185; 5,485,879; 5,574,822; 5,596,952; 5,660,165; 5,682,666; 5,761,379; 5,943,984; 5,954,492; 5,988,117; 6,142,216. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING.
CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515.

Commercial Electric Energy Saver

Sample Specification
The water heater shall be a Bradford White model with a rated storage capacity of not less than ___________gallons/ liters, a minimum KW input of __________, and a minimum recovery of _____ GPH/LPH at 100oF (56oC) temperature rise. It shall be design certified either with or without a separate storage tank. The tank shall be lined with Vitraglas® vitreous enamel and shall have a bolted hand hole cleanout. The tank shall have extruded magnesium anode rods installed in separate head couplings and extended to within three inches (76mm) of the bottom. The heater shall be insulated with not less than 3" (51mm) of Non-CFC foam. This water heater shall be equipped with an ASME rated T&P relief valve. The entire installation shall be made in compliance with state and local codes and ordinances. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.