- 要清洗过滤器;先拆卸过滤器塞(2),然后拆卸和清洗过滤器。
To clean strainer; remove strainer plug (2), remove
and clean strainer.
- 要更换阀座阀瓣,先关闭供应管道,松开螺母(51),拧下调节螺丝(53),拆卸弹簧笼(3)、弹簧(52)和垫圈(62)。拆卸底部塞(12)和垫圈(101)。将螺丝刀插入并停留在阀杆顶部的槽内,然后从阀杆(27)底部松开阀座阀瓣支架(47)。
To replace seat disc; shut off supply, loosen
nut (51) and back off adjusting screw (53) remove spring cage (3), spring
(52) and washer (62). Remove bottom plug (12) and gasket (101). Insert
and hold screw driver in slot on top of stem while loosening seat disc
holder (47) from bottom of stem (27).
- 要更换隔膜,先松开锁紧螺母(48),并拆卸锁紧垫圈(46),隔膜板(60)和隔膜(20)。
To replace diaphragm; loosen lock nut (48) and
remove lock washer (46), diaphragm plate (60) and diaphragm (20).
- 在重新组装时,将一个低强度螺纹装置锁到阀瓣支架上。
When reassembling apply a drop of low strength
thread lock to disc holder.
调节
Adjustment
工厂预置的调节阀压力为50psi。要调节压力设置,先松开锁紧螺母,然后顺时针旋转调节螺栓以增加压力,逆时针旋转以降低压力。
注:在下游采用一个压力表,用来调节和核实压力设置。
Regulator is factory preset to 50psi. To adjust
pressure setting, loosen the lock nut and turn the adjusting bolt clockwise
to increase pressure, counter clockwise to decrease pressure.
Note: Use a pressure gauge downstream to adjust and verify the pressure
setting.
旁路特点*
By-Pass Feature*
这种调节阀配置一个内置热膨胀旁路。这种旁路可以防止下游压力升高超过供应压力10psi以上。*如果进口压力超过150psi (10.34
bars),则旁路将不起作用。
This regulator has a built-in thermal expansion
by-pass feature. This feature prevents downstream pressure from rising
to more than 10psi above the supply pressure. * By-Pass will not work
if inlet pressure is above 150psi (10.34 bars).
故障排除
Troubleshooting
高系统压力
High System Pressure
如果在无流量情况下,下游系统压力高于设置压力,则原因可能是热膨胀,压力蠕变或阀座上的污垢/碎片。
If the downstream system pressure is higher than
the set pressure under no flow conditions, the cause could be thermal
expansion, pressure creep or dirt/debris on the seat.
只有当水在封闭系统内加热时才会发生热膨胀。在供应压力超过150psi,或供应管道上安装一个止回阀或防倒流阀时,系统被关闭。
Thermal expansion occurs whenever water is heated
in a closed system. The system is closed when supply pressure exceeds
150psi, or a check valve or backflow preventer is
installed in the supply piping.
用户必须采取压力释放的措施,以保护用户的管道系统和部件。可能需要采用安全阀,如美国瓦茨530C, BRV, Governor 80, 或3L,或饮用水膨胀罐,如美国瓦茨DET,
PLT或DETA等。
You must make provisions for pressure relief protection
of your plumbing system and components. The use of a relief valve such
as the Watts 530C, BRV, Governor 80, or 3L or potable water expansion
tank such as the Watts DET, PLT or DETA may be required.

美国瓦茨276H300
Watts 276H300 |
为了确定是否是热膨胀的原因,请尝试短暂开启冷水龙头。如果压力增加,则说明原因就是热膨胀,此时要立即释放压力,让系统恢复到设置压力上。美国瓦茨提供压力测试表,型号276H300,帮助用户确定是否存在高水压。当把型号276H300附在软管龙头上,并留在系统一段时间,则表上将显示最大压力读数。
To determine if this is the result of thermal
expansion, try briefly opening the cold water tap. If the increased
pressure is caused by thermal expansion, the pressure will immediately
be relieved and the system will return to the set pressure. Watts
offers a pressure test gauge, model 276H300 to assist you in determining
if you have high water pressure. The 276H300 when attached to a hose
bibb registers the highest pressure reading over the period of time
it is left on the system. |
|
|

† 橡胶部件
* 可更换
** 不可更换
† Rubber Parts
* Replaceable
** Non-Replaceable
| (53) |
调节螺丝
Adjusting Screw |
|
(51) |
锁紧螺母
Lock Nut |
| (3) |
弹簧笼
Spring Cage |
|
(61) |
弹簧垫圈
Spring Washer |
| (52) |
弹簧
Spring |
|
(48) |
锁紧螺母
Lock Nut |
| (46) |
锁紧垫圈
Lock Washer |
|
(60) |
隔膜板
Diaphragm Plate |
| (20) |
隔膜 †
Diaphragm † |
|
(102) |
旁路阀门垫圈*
By-Pass Valve Gasket* |
| (116) |
旁路阀门总成
By-Pass Valve Assembly* |
|
(103) |
O形环 †
O-Ring † |
| (27) |
阀杆
Stem |
|
(16) |
阀座 †
Seat † |
| (42) |
垫圈
Washer |
|
(37) |
阀瓣 †
Disc † |
| (47) |
阀瓣支架
Disc Holder |
|
(104) |
过滤器塞垫圈 †
Strainer Plug Gasket † |
| (2) |
过滤器塞
Strainer Plug |
|
(6) |
旁路球**
By-Pass Ball** |
| (77) |
过滤器
Strainer |
|
(101) |
底部塞垫圈 †
Bottom Plug Gasket † |
| (12) |
底部塞
Bottom Plug |
|
|
|
| |
维修组件
Repair Kits
† 适用于系列25AUB-Z3的组件,包括所有上述显示的项目。
† Kit for Series 25AUB-Z3 includes all
items shown above. |
订购编号
ORDERING CODE |
组件编号
KIT NO. |
通径(DN)
SIZE (DN) |
| |
|
英寸
in |
毫米
mm |
| 0864941 |
1/2" LF 25AUB-RK |
1/2 |
15 |
| 0864943 |
1/2" LF 25AUB-RK |
3/4 |
20 |
| 0864942 |
1" LF 25AUB-RK |
1 |
25 |
| 0864944 |
11/4" LF 25AUB-RK |
11/4 |
32 |
| 0864945 |
11/2"" LF 25AUB-RK |
11/2 |
40 |
| 0864946 |
2" LF 25AUB-RK |
2 |
50 |
| |
在订购时,请指明:
When Ordering, Specify: |
1. 订购编号
2. 阀门通径
1. Ordering Code
2. Size of Valve |
3. 类型编号
4. 铭牌上显示的型号
3. Type Number
4. Model shown on Nameplate |
警告
WARNING
对于采用CPVC或PEX连接端口的阀门,不要超过管道制造商额定的压力和温度。请参阅管道制造商产品规格说明,了解更多的信息。
For valves with CPVC or PEX end connections
do not exceed the tubing manufacturers pressure and temperature
ratings. Refer to the tubing manufacturers product specifications
for that information. |
美国加州提议65警告
CALIFORNIA PROPOSITION 65 WARNING
警告:美国加州已知这种产品包含可能导致癌症和生育障碍或其它有害生育的化学物质。(美国加州法律要求在美国加州境内将此类产品提供给用户时要提出警告。)
WARNING: This product contains chemicals
known to the State of California to cause cancer and birth defects
or other reproductive harm. (California law requires this warning
to be given to customers in the State of California.) |
|