| 美国Yeomans(约曼)9235系列干井潜水泵是固体颗粒污水处理泵,其结构坚固耐用,质量优异,维护成本低,并配置专利技术的闭环冷却系统。这种独特的“CLC”
电机设计不需要外加水保护罩,避免了与“污水冷却”设计所带来的问题。
Yeomans Series 9235 dry-pit submersible pumps
provide rugged solids-handling pump construction and a quality, low maintenance,
patented closed-loop cooling system. The unique “CLC” motor design eliminates
the need for external water jackets and the problems associated with “sewage-cooled”
designs.
·专利技术的“CLC”(闭环冷却)电机*
·Patented "CLC" (Closed-Loop-Cooled)
Motor*
·IP68电机保护
·IP68 motor protection
·电机都是按照NEMA(美国全国电动机协会)MG-1和IEEE(美国电气与电子工程师协会)标准设计并或其认证
·Motors designed and rated per NEMA MG-1 and IEEE
standards
·流量最大可达10,000 USGPM(美制加仑/分钟)或2,271 m3/hr(立方米/小时)
·Capacities to 10,000 USGPM (2,271 m3/hr)
·扬程最大可达300英尺(91米)
·Heads to 300 feet (91m)
·温度达187oF (90oC)
·Temperatures to 187 F (90 C)
·压力达200 PSIG (1378 kPa)
·Pressures to 200 PSIG (1378 kPa)
·排泄出口直径从4英寸(102mm)至20英寸(508mm)
·Discharge Sizes from 4" (102mm) to 20"
(508mm)
·固体(颗粒)尺寸达6英寸(152mm)
·Solids (sphere size) to 6" (152mm)
·标准“21类”机械密封,成本低并且从当地其它供应商处即可购买到
·Standard "Type 21" mechanical seals
for low-cost and quick availability from local sources
·在出现非正常情况时,“支柱”密封环设计能够保证更长的使用寿命和稳定可靠性
·"Solid-Block" seal ring design assures
long life and reliability under upset conditions
·双重防潮保护的探针能够避免警报失灵或误报
·Dual moisture detection probes to eliminate false
alarms
·接线端子板的电缆连接方式,便于电缆的迅速装配和更换
·Terminal Board cable connection for quick replacement
of the cap/cable assembly
·环氧树脂保护的电缆进口,有利于防止潮气通过电源/控制电缆进入电机
·Epoxy-potted cable entry prevents moisture from
entering the motor via the power/control cables
·电机线圈内的热控开关用于过热保护
·Thermal switches in motor windings for over-temperature
protection
·可根据特殊的应用要求提供配置特制泵结构材料的各种大小的泵。
·All sizes available with special pump-end materials
of construction to meet the specific application requirements
*闭环冷却干井潜水电机设计采用专利技术的自动冷却系统。与其它竞争者的设计不同的是,“CLC”系统并不采用内部循环的污水进行冷却,因此就避免了电机过热和冷却通道被堵塞而导致的电机过早损坏。同时,也避免了对冷却通道进行定期的清洗和冲刷。
* The Closed-Loop-Cooled dry-pit submersible motor
design utilizes a patented cooling self-contained cooling system. Unlike
many competitors’ designs, the "CLC" system does not utilize
internal circulation of the dirty sewage water for cooling, thereby eliminating
motor overheating and premature failure caused by clogged cooling passages.
The need for periodic cleaning and flushing of cooling passages is eliminated.
|